End of pipe treatment device

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The basic principle of the end of pipe treatment device is to collect various harmonic currents on the neutral line of the system through the current detection link, quickly calculate and extract the content of each harmonic current through the controller, generate harmonic current instructions, and output compensation current with the same amplitude and opposite direction as the harmonic current through the power execution device. The compensation current is injected into the neutral line to eliminate the neutral line current.
Product Details

1、 The concept of neutral wire

The IEC standard refers to the conductor carrying multiphase unbalanced currents as the neutral wire (N-wire), also known as the "neutral wire". In the windings of transformers and generators, there is a point where the absolute value of the voltage between the external terminals is equal to the neutral point. The conductor led out from the neutral point is called the neutral wire.

During the operation of three-phase four wire or five wire power supply systems, fire accidents caused by neutral wires are mainly caused through three ways:

Long term overload of the neutral wire leads to aging of the neutral wire insulation layer, ultimately causing the insulation layer to burn and trigger a fire;

A neutral wire fault causes an open circuit in the neutral wire, resulting in a serious imbalance of three-phase electricity and burning electrical equipment, leading to a fire.

The aging of the neutral wire causes local overheating of the circuit, leading to the aging of the neutral wire insulation layer, and ultimately causing the insulation layer to burn and trigger a fire.

IIend-of-pipe treatmentdevicePrinciple features

End of pipe treatment deviceThe basic principle is to collect various harmonic currents on the neutral line of the system through the current detection link, quickly calculate and extract the content of each harmonic current through the controller, generate harmonic current instructions, and output compensation current in the opposite direction to the amplitude of the harmonic current through the power execution device. The compensation current is injected into the neutral line to eliminate the neutral line current.